Benchtop Multi-parameter Water Quality Meter

LMPWM-A30 Benchtop Multi-parameter Water Quality Meter LMPWM-A30

pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point

Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C

TDS Mode : TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1  to 1.0 (default 0.5)

LMPWM-A31 Benchtop Multi-parameter Water Quality Meter LMPWM-A31

pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point

Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C

TDS Mode : TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1  to 1.0 (default 0.5)

LMPWM-A32 Benchtop Multi-parameter Water Quality Meter LMPWM-A32

pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point

Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C

Dissolved Oxygen Mode : Dissolved Oxygen Range 0.00 to 20.00 mg/ L Dissolved Oxygen Accuracy ± 0.2 mg/ L Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable Dissolved Oxygen Calibration Points 1 or 2 Points % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg Salinity correction 0 to 50 g/ L

LMPWM-A40 Benchtop Multi-parameter Water Quality Meter LMPWM-A40

pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

ORP Mode : mV Range ± 2000 mV mV Accuracy ± 0.2 mV mV Resolution 0.1 mV, selectable mV Calibration Points 1 Point, only for relative mode

Ion Mode : Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Ion measurement resolution 0.001/0.01/0.1/1 Ion measurement calibration points 2 to 5 points Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction

Water Hardness Mode : Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3) Water hardness measurement accuracy ±1% F.S Water hardness measurement resolution 0.001/0.01/0.1/1 Water hardness calibration points 2 to 5 points Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L