Plasma Autoclave LPA-A12

Plasma Autoclave LPA-A12

Plasma Autoclave LPA-A12 is a 240 Liters vertical single cycle sterilization unit. Equipped with H2O2 purification device with minimum 3 sterilization programmes. Real time monitorisation of sterilization process with automatic system failure detection and unlocking at the end the cycle helps in having no operator intervention. Built in hand protected infrared ray design makes it a user friendly and safe to use device.

Request Quote
Capacity 240 L
Door type Rectangular, double door
Chamber material Anti rust aluminum alloy
Power supply 3 kW / 220 V, Single phase
Sterilizing agent 60 % H2O2
Working temperature 50 ~ 55 ºC
Standard sterilization time ≤ 45 mins
Vacuum ≤ 60 Pa
Sealing time Up to 0.5 seconds
Chamber size 650 × 550 × 780 mm
Outer size 1070 × 1920 x 1020 mm
Gross weight 440 kg
  • Single-cycle sterilization process
  • Automated drying function with door unlocking at the end of every cycle
  • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
  • Self-inflating leak proof chamber
  • Automatic power cut off with alarm with low water levels indication
  • Hand protected infrared ray design for user safety
  • Safe door lock system ensuring safety / protection during sterilization
  • Automatic fault detection with real time monitoring of sterilization process

Used to sterilize delicate instruments that are heat and moisture sensitive such as micro instruments, cameras, scopes and light cords in a toxic free environment

Compare Models

Model Capacity Door type Chamber material Power supply Sterilizing agent Working temperature Standard sterilization time Vacuum Sealing time Chamber size Outer size Gross weight
LPA-A10 80 L Rectangular, single door Anti rust aluminum alloy 3 kW / 220 V, Single phase 60 % H2O2 50 ~ 55 ºC ≤ 45 mins ≤ 60 Pa Up to 0.5 seconds 450 × 312 × 670 mm 696 × 1440 × 923 mm 210 kg
LPA-A11 120 L Rectangular, single door Anti rust aluminum alloy 3 kW / 220 V, Single phase 60 % H2O2 50 ~ 55 ºC ≤ 45 mins ≤ 60 Pa Up to 0.5 seconds 450 × 410 × 780 mm 816 × 1798 × 1020 mm 270 kg
LPA-A12 240 L Rectangular, double door Anti rust aluminum alloy 3 kW / 220 V, Single phase 60 % H2O2 50 ~ 55 ºC ≤ 45 mins ≤ 60 Pa Up to 0.5 seconds 650 × 550 × 780 mm 1070 × 1920 x 1020 mm 440 kg
LPA-B10 - Rectangular type, sliding door Anti-corrosion type SUS 304 stainless steel heating method AC220 V, 50 Hz 60 % (H2O2) hydrogen peroxide - - - - - - 340 kg
LPA-B11 - Rectangular type, sliding door Anti-corrosion type SUS 304 stainless steel heating method AC220 V, 50 Hz 60 % (H2O2) hydrogen peroxide - - - - - - 360 kg
LPA-B12 - Rectangular type, sliding door Anti-corrosion type SUS 304 stainless steel heating method AC220 V, 50 Hz 60 % (H2O2) hydrogen peroxide - - - - - - 450 kg
LPA-B30 - Manual door opening, vertical Anti-corrosion type 5052 aluminum alloy, thickness ≥ 8mm AC220 V, 50 Hz 60 % (H2O2) hydrogen peroxide - - - - - - 270 kg
LPA-C10 120L - - - - - - - - - - -