Table top spectrophotometer LTS-A13

Table top spectrophotometer LTS-A13


Transmitted spectrophotometer LTS-A13 with table top design, side ward caliber is used to measure the transmittance as well as reflectance. The use of D/0 diffused light, CLEDs, dual optical path spectrum analysis technology & ETC every test calibration technology gives 0.01% resolution, balance intensity across visible spectrum & highly accurate measurements.




Share :


Illumination systemd/0 (Diffused lighting, 0° observation viewing)
Size of integrated sphere40 mm, alvan diffused reflection surface coating
Illumination light sourceCLED
SensorDual light path sensor array
Light sourceA, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF
Wavelength range400 - 700 nm
Wavelength interval10 nm
Half spectral width5 nm
Reflectivity range & resolution0 to 200 %, 0.01 %
Observation Angle2°/10°
Measurement time interval0.5 s
Measurement time2 s
Measuring aperture25.5 × 10 mm (cuvette support)
Color spaceCIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK
Color difference formulaΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 color classification
Other colorimetric indicesWI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,Ganz, Stensby)
YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz)
Metamerism index Milm, staining fastness, color fastness, APHA, Astm color, ISO illuminance, saybolt
RepeatabilityTransmittance: standard deviation within 0.08%
color values:ΔE*ab <= 0.015
(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03
Data being displayedSample's color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report
InterfaceUSB
Data storageMass storage (on PC)
Light source longevity5 years, 1.5 million tests
Dimension (L × W × H)475 × 340 × 150 mm
Weight7 kg
Work temperature range0 °C to 45 °C, relative humidity 80 % or below (at 35 °C), no condensation
Storage temperature range(-25 ℃ to 55 ℃) relative humidity 80 % or below(at 35 °C ),no condensation
  • Use of D/0 Diffused lighting, 0° observation viewing)
  • Use of CLED guarantees the speed of the measurement & accuracy of the results
  • Both SCI & SCE includes lightening & observation conditions
  • Can be connected to PC software
  • SCS system for best measurement repeatability & measurement of surface colors
  • Use of UV enhanced silicon photodiode
  • Adopted with ETC for reliability & higher accuracy
  • Glass and liquid color measurement
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.