Real Time PCR LRTP-B10

Real Time PCR LRTP-B10


From isolation to discovery and quantification to pathogen detection, our product is your perfect partner for exploring applications that involves polymerase chain reactions. Sensitive and reliable fluorescence quantitative PCR detection system delivers an unsurpassed performance, its large sample size increases productivity. Wide fluorescence wavelength range with innovative eight channel design, it optimizes thermal performance and maximizes convenience during operation.

Sample Capacity96-Well PCR plate12×8-strip
96×0.2ml(Bottom Transparent)
Emission Wavelength500-800nm
Excitation Wavelength300-800nm
Sample Volume Range5 ~100μl
ProgramMax 20 Segments for Each Program, Max 99 Cycles
Dynamics Range10~1010Copies
Max. channels number of fluorescence detection2 channels
Detected FluorescenceF1: FAM, SYBR Green 1; F2:VIC HEX TET JOE
Block Temp. Range4~105 ℃ ( Minimum Increment: 0.1 ℃ ), SOAK Low Temp.Conservation Function
Temp. Control Accuracy≤±0.1 ℃
Temp. Fluctuation≤±0.1 ℃
Temp. Uniformity≤±0.3 ℃
Heating Rate4.0 ℃/sec
Temp. Control ModeBLOCK/Tube Simulation Mode (Automatic Control based On Sample Volume )
Gradient Temp. Range1 ~36 ℃
Hot-lid Temp. Range30 ~110 ℃ (Adjustable, default 105 ℃, Automatic Hot-lid )
Fluorescence Detection Repeatability0.05
Operation ModeContinuous
Scan ModeEntire Plate or Designated Line
Scan Period5.5sec (F1/F2 96 plate scan)
Operation SystemMicrosoft: Windows2000/XP/vista/Windows7 Software: Excel2003/2007 Access: 2003/2007
PC ConfigurationMemory:512M; Hard Disk:10GB; CPU:Pentium® 4; Virtual Memory:≥1000MB
Power Supply100-240V ~ 50/60Hz 600W
Dimension ( L×W×H )430x395x352mm
SocketRS 232C Adapter, USB adapter (optional), Bluetooth adapter (optional)
  • Ferrotec Peltier cooler with improved efficiency and longer life
  • Patented block dissipation technology gives excellent temperature uniformity
  • Eight individual filters cover wide range of wavelength
  • Wide range of block temperature (4-105°C) with SOAK low temperature function; Easy data transfer via USB and Bluetooth
  • Upto 96 well capacity with fast speed dual colour scanning
  • Temperature gradient control upto 36°C gradient
  • Panoramic view of experimental results
  • Baseline\threshold and linreg analytical methods for individual analysis of each sample
Ideal solution for sequencing, genotyping, cloning, mutagenesis and routine applications that require quantification and characterization of nucleic acids in academic institutes, research centres, diagnostics and laboratories.