info@labtron.com +44 2080 043608
Tensile Stiffness Tester TP-B10

Tensile Stiffness Tester TP-B10

Tensile Stiffness Tester TP-B10 is a used to measure the bending resistance (stiffness) of paper and paperboard. It is designed in accordance with working principle of international ‘Static bending method’, where the curvature of a vertical clamping specimen comes with free end, It can take the specimen to a certain bending angle when the resistance is the bending stiffness, and the unit is mN, resistance and test product of length will be in mN.m.

Request Quote
Sample (size) length 38×70 mm
Measuring range (1-500) mN.m (divided into 7 small ranges)
Indication error 0.02
Test speed (200° ± 20°)/ min
Dimension (L*W*H) 220 × 230 × 350 mm
Net weight 15 kg
Power supply 220 V ± 10 %, 50 Hz
  • Incorporation of international static bending method design
  • Measuring range (1-500) mN.m (divided into 7 small ranges)
  • Sample size 38×70 mm
  • Test speed (200° ± 20°)/ min

Tensile Stiffness Tester is used in paper & cardboard paper making industry, packaging industry to measure the stiffness of material.

Compare Models

Model Sample (size) length Sample width Measuring range Measurement mode Stability Accuracy Tensile strength velocity Tensile return velocity Sample loading Clamp air pressure Repeatability System Light source Zero drift Indication drift Indication error Test speed Repeatability error Mirror reflection error Light measurement Storage Dimension (L*W*H) Net weight Power supply
TP-A10 Diameter ≥30 mm, Thickness ≤ 40 mm - - Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b ≤ 0.1 within 30 min Chromaticity co-ordinate 0.0001 - - - - Rx, Ry and Rz s ≤ 0.1 chromaticity co-ordinate s ≤ 0.0010, R457 s ≤ 0.10 D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150 mm, testing hole diameter 30 mm - - - - - - - CIE whiteness (Ganz whiteness W10, Color cast value TW10), WH hunter whiteness, YI Yellowness, ISO brightness R457 9 reference samples 360 × 264 × 400 mm 23 kg 220 V ± 10 %, 50 Hz
TP-A11 Diameter ≥30 mm, Thickness ≤ 40 mm - - - - - - - - - - D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm D65 as illuminating source ≤ 0.1 % ≤ 0.1 % ≤ 0.5 % - ≤ 0.1 % ≤ 0.1 % - - 360 × 264 × 400 mm 20 kg 220 V ± 10 %, 50 Hz
TP-B10 38×70 mm - (1-500) mN.m (divided into 7 small ranges) - - - - - - - - - - - - 0.02 (200° ± 20°)/ min - - - - 220 × 230 × 350 mm 15 kg 220 V ± 10 %, 50 Hz
TP-B11 90 to 200 mm 15 mm, 25 mm, 50mm 0 to 30, 0 to 100 N,0 to 300 N - - ± 1 % 1 to 399 mm/min (adjustable) 1 to 399 mm/min (adjustable) Full automatic to clamp the sample 0.4 to 0.6 MPa - - - - - - - - - - - 920 × 420 × 300 mm 65 kg 220 V ± 10 %, 50 Hz
TP-B12 180 mm (180, 150, 100, 90, 50 mm adjustable) 15 mm 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - ± 1 % 1 to 399 mm/min (adjustable) 1 to 399 mm/min (adjustable) Semi-automatic , can clamp the sample using hands - - - - - - - - - - - - 800 × 270 × 200 mm 40 kg 220 V ± 10 %, 50 Hz
TP-B20 0 to 200 mm adjustable 15 mm 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - ± 1 % 1 to 399 mm/min (adjustable) 1 to 399 mm/min (adjustable) - - - - - - - - - - - - - 450 × 550 × 120 mm 55 kg 220 V ± 10 %, 50 Hz
TP-C10 - - - - - - - - - - - - - - - - - - - - - - - -
TP-C20 - - - - - - - - - - - - - - - - - - - - - - - -
TP-C21 - - - - - - - - - - - - - - - - - - - - - - - -
TP-C30 - - - - - - - - - - - - - - - - - - - - - - - -
TP-D10 - - - - - - - - - - - - - - - - - - - - - - - -
TP-E10 - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-E20 - - 0 to 4 mm - - 0.01 or 0.001 mm - - - - - - - - - - - - - - - - - -
TP-E21 - - 0 to 20 mm - - 0.01 mm - - - - - - - - - - - - - - - - - -
TP-F10 - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-G10 - 15 mm - - - - - - - - - - - - - - - - - - - - - -
TP-H10 - - 10 to 1000 mN - - ± 1% - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-I10 - - 0.1 to 10 kN - - - - - - - - - - - - < ± 1% - - - - - - - AC220 V ± 10 % , 50 Hz
TP-I11 - - 1 to 50 kN - - - - - - - - - - - - < ± 1% - - - - - - - AC220 V ± 10 % , 50 Hz
TP-J10 - - 0 to 1000 ml/min - - - - - - - - - - - - - - - - - - - - -
TP-J11 - - - - - - - - - - - - - - - - - - - - - - - -
TP-J12 - - A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
- - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-J20 - - 0 to 1000 mN - - - - - - - - - - - - ± 1 % - - - - - - - -
TP-J21 - - - - - - - - - - - - - - - - - - - - - - - -
TP-K10 - - - - - ± 0.5 % F.S. - - - - - - - - - - - - - - - - 65 kg AC220 V ± 10 % , 50 Hz
TP-K11 - - - - - ≤± 0.5 % - - - - - - - - - - - - - - - - 50 kg AC220 V ± 10 % , 50 Hz
TP-L10 - - - - - ± 1 % - - - - - - - - - - - - - - - - 75 kg AC220 V ± 10 % , 50 Hz
TP-L20 - - - - - ±0.1 s within 300 s - - - - - - - - - - - - - - - - 30 kg AC220 V ± 10 % , 50 Hz
TP-M10 - - - - - - - - - - - - - - - - - - - - - - 35 kg AC220 V ± 10 % , 50 Hz
TP-E30 - - 0 to 5 mm - - - - - - - - - - - - ± 0.0025 mm or ± 0.5 % - - - - - - - -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608