info@labtron.com +44 2080 043608
Paper air permeability tester TP-J10

Paper air permeability tester TP-J10

Paper air permeability tester TP-J10 is designed to measure the air permeability under specified conditions with time & unit pressure difference. It measures the average air flow through the unit area of the sheets. It is incorporated with standard ‘Paper porosity method’ used to test paper permeability. It is suitable for paper porosity with 1 x10 ˉ ² to 1 x10 ² µ m/ (Pa · S) range, and not suitable for large rough texture paper.

Request Quote
Measuring range 0 to 1000 ml/min
Test area 10 ± 0.02 cm2
Area differential pressure 1 ± 0.01 kPa
Inner diameter of grip ring 35.68 ± 0.05 mm
Dimension 410×300×1160 mm
Weight About 15kg
  • Measuring range 0 to 1000 ml/min
  • Measure air permeability of different type of papers
  • Delicate benchtop standing model design
  • Incorporated with ‘Paper porosity method’
  • User-friendly operations

Paper air permeability tester is used to measure air permeability of papers like cement sack paper, craft paper, cable paper, copy paper and industrial filter paper used in paper, packaging, craft industry.

Compare Models

Model Measuring range Capacity Resolution Indication error Tearing arm Tearing angle Chips distance Clamp- paper Resection length Tearing distance Frictional resistance Pyramid dimension Platen Size Operating stroke Compression speed Impact angle Unit Error Sample amount Speed adjustment range Track & force speed in stacking test Test area Area differential pressure Inner diameter of grip ring Dimension Weight Power supply
TP-A10 - - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-A11 - - - ≤ 0.5 % - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B10 (1-500) mN.m (divided into 7 small ranges) - - 0.02 - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B11 0 to 30, 0 to 100 N,0 to 300 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B12 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B20 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-C10 - - - - - - - - - - - - - - - - - - - - - - - - 450×250×1100 mm - -
TP-C20 - - - - - - - - - - - - - - - - - - - - - - - - 420×250×380 mm - -
TP-C21 - - - - - - - - - - - - - - - - - - - - - - - - 270×400×300 mm - -
TP-C30 - - - - - - - - - - - - - - - - - - - - - - - - 240×288×435 mm - -
TP-D10 - - - - - - - - - - - - - - - - - - - - - - - - - - -
TP-E10 - - - - - - - - - - - - - - - - - - - - - - - - 200×230×350 mm 15 kg AC220 V ± 10 % , 50 Hz
TP-E20 0 to 4 mm - - - - - - - - - - - - - - - - - - - - - - - 233×160×120 mm 5.5 kg -
TP-E21 0 to 20 mm - - - - - - - - - - - - - - - - - - - - - - - 233×160×120 mm 5.5 kg -
TP-F10 - - - - - - - - - - - - - - - - - - - - - - - - 275×302×297 mm 25 kg AC220 V ± 10 % , 50 Hz
TP-G10 - - - - - - - - - - - - - - - - - - - - - - - - 240×520×70 mm 4 kg -
TP-H10 10 to 1000 mN - - - - - - - - - - - - - - - - - - - - - - - 570×410×200 mm 33 kg AC220 V ± 10 % , 50 Hz
TP-I10 0.1 to 10 kN - - < ± 1% - - - - - - - - 500×500 mm (customized) 500 mm (customized) 10 mm/ min - - - - 2 to 100 mm/ min 2 mm/ min - - - - - AC220 V ± 10 % , 50 Hz
TP-I11 1 to 50 kN - - < ± 1% - - - - - - - - 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized) 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized) 10 mm/ min - - - - 2 to 100 mm/ min 2 mm/ min - - - - - AC220 V ± 10 % , 50 Hz
TP-J10 0 to 1000 ml/min - - - - - - - - - - - - - - - - - - - - 10 ± 0.02 cm2 1 ± 0.01 kPa 35.68 ± 0.05 mm 410×300×1160 mm About 15kg -
TP-J11 - A: 20 to 500 J/m2 B: 500 to 1000 J/m2 - - - - - - - - - - - - - 90° Lb-ft/in2  J/m2 A: ± 1 J/m2 B: ± 2 J/m2 5 pcs - - - - - 700×340×600 mm 92    g -
TP-J12 A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
- - - - - - - - - <0.25 J Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm - - - - - - - - - - - - 800×470×840 mm 185 kg AC220 V ± 10 % , 50 Hz
TP-J20 0 to 1000 mN - 0.1 mN ± 1 % 104 ± 1 mm 27.5° ± 0.5° - - - 43 ± 0.5 mm - - - - - - - - - - - - - - - - -
TP-J21 - 10 -16000 mN 0.1 mN - 104 ± 1 mm 27.5° ± 5° 180 mm 2.8 ± 0.3 mm 20 ± 0.5 mm - - - - - - - - - - - - - - - - 20 kg -
TP-K10 - - - - - - - - - - - - - - 170 ± 15 ml/min - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-K11 - - 0.01 kPa - - - - - - - - - - - 95 ± 5 ml/min - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-L10 - - 1 N - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-L20 - - - - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-M10 - - - - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-E30 0 to 5 mm - - ± 0.0025 mm or ± 0.5 % - - - - - - - - - - - - - - - - - - - - - 25 Kg -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608