Chromatography is a powerful analytical tool that is widely used in research, quality control, and various industries. It allows scientists to identify, quantify, and purify substances within complex mixtures, making it an essential technique in fields such as pharmaceuticals, food and beverage, forensics, and environmental monitoring. There are many different types of chromatography, including gas chromatography (GC), gas chromatography-mass spectrometry (GC-MS), ion chromatography (IC), and liquid chromatography-mass spectrometry (LC-MS). Each type of chromatography has its own strengths and weaknesses, and the best type to use will depend on the specific application.
High pressure pump : Single pump
Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range : ≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision : RSD < 0.06 %
High pressure pump : Two sets of pump
Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range : ≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision : RSD < 0.06 %
High pressure pump : High pressure gradient pump
Peak operating pressure : 45 MPa, Stainless steel pump
Pressure : ± 0.02 MPa
Flow rate range : 0.001 - 9.999 mL / min
High pressure pump : High pressure constant-current infusion pump
Infusion Way : Micro volume series dual-piston
Infusion pressure : 0 - 9999 Psi
Flow rate : ≤ 0.5 %
Pump Type : Quaternary Low-Pressure Pump
Pump Flow Rate Range : 0.001 to 10.000 ml/min, in 0.001ml increments
Pump Flow Accuracy : ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
Pump Flow Precision : RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
Pump Flow Range : 0.001 to 10.000mL/min
Pump Set Step : 0.001mL/min
Pump Pressure Range : 0 to 42 MPa
Pump Pressure Pulsation : 0.1MPa (10MPa, C18, methanol 1mL/min)
Detector Specifications : Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg
Mass Range : m/z 2 to 2,000
Resolution : R < 0.7 u FWHM and adjustable to 0.5 u
Scan Speed : ≥2,0000 amu/s
Ionization Switching Time : 20 ms