info@labtron.com +44 2080 043608
Nucleic Acid Purification System LNAP-A20

Nucleic Acid Purification System LNAP-A20

Nucleic Acid Purification System LNAP-A20 is a benchtop unit comes with sample quantity of 10 and process volume ranges from 50 to 1000 µl. Adopted with magnetic bead separation technology with consumable of 5 ml tube strip and magnetic rod’s tip. Offers elution temperature ranges from ambient temperature to 120°C and lysis temperature ranges from ambient temperature to 120°C. Built-in exhaust fan, lighting LED lights to observe running status of the instrument in real time and 4.3 inch touch screen display. Integrated with program management includes PC software, APP software, program editing, setting and management procedures.

Request Quote
Maximum Sample Volume 5 ml
Sample Quantity 10
Process Volume 50 to 1000 µl
Consumable 5 ml tube strip+ Magnetic rod’s tip
Throughput 1 to 10
Block Heating None
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Purification Accuracy 100 Copy sample positive rate > 95 %
Stability CV < 5 %
Collection Efficiency > 95 %
Mixing Mixing methods is editable according to different requirements
Operation Interface 4.3 inch touch screen, 3 shortcut keys, external mouse
Built-in Protocol Pre-set 6 group programs, 100 pcs program can be saved
Program Management PC software, APP software, Program editing, Easier management
Extension Interface Standard USB, LAN, Wi-Fi
Lighting Yes
Pollution Control UV light
Exhaust Way By Fan
Data Storage Built-in SD card
Maximum Input Power 300 W
Dimension 340×350×410 mm
Weight 18 kg
  • High yield of nucleic acid with low magnetic bead loss and good repeatability of results
  • Large guide rail design offers more reliable structure and Screw rod design provide high operating accuracy
  • 4.3 inch touch screen display for ease of monitoring various parameters
  • Space saving design with maximum sample volume of 5 ml
  • 10 samples can be processed at a same time
  • Avoid cross contamination and provide UV disinfection
  • Integrated with elution, lysis and heating function
  • Manual setting of open instrument parameters
  • APP software (Android system) which can monitor the system in real time through mobile device
  • Built in with function such as QR code identification, magnetic absorption and release, mixing speed, cooling fan and other function

Nucleic Acid Purification System is widely used in extraction of nucleic acids in animal and plant tissues, blood, body fluids, criminal examinations, DNA and RNA. It is suitable to use in molecular biology, biotechnology, immunology, cell and microbiology.

Tube Strips
Magnetic Rod's Tip

Compare Models

Model Maximum Sample Volume Sample Quantity Process Volume Consumable Throughput Block Heating Lysis Temperature Elution Temperature Purification Accuracy Stability Collection Efficiency Mixing Operation Interface Built-in Protocol Program Management Extension Interface Lighting Pollution Control Exhaust Way Data Storage Maximum Input Power Dimension Weight
LNAP-A20 5 ml 10 50 to 1000 µl 5 ml tube strip+ Magnetic rod’s tip 1 to 10 None Ambient temperature to 120°C Ambient temperature to 120°C 100 Copy sample positive rate > 95 % CV < 5 % > 95 % Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse Pre-set 6 group programs, 100 pcs program can be saved PC software, APP software, Program editing, Easier management Standard USB, LAN, Wi-Fi Yes UV light By Fan Built-in SD card 300 W 340×350×410 mm 18 kg
LNAP-A21 5 ml 10 50 to 1000 µl 5 ml tube strip+ Magnetic rod’s tip 1 to 10 Yes (RT + 5°C to 105°C) Ambient temperature to 120°C Ambient temperature to 120°C 100 Copy sample positive rate > 95 % CV < 5 % > 95 % Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse Pre-set 6 group programs, 100 pcs program can be saved PC software, APP software, Program editing, Easier management Standard USB, LAN, Wi-Fi Yes UV light By Fan Built-in SD card 350 W 340×350×410 mm 18.5 kg
LNAP-A30 - 16 50 to 1000 µl 96 Deep well plate and Magnetic rod’s tip 1 to 16 None Ambient temperature to 120°C Ambient temperature to 120°C - CV < 5 % > 95 % Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse Pre-set 6 group programs, 100 pcs program can be saved PC software, APP software, Program editing, Easier management Standard USB, LAN, Wi-Fi Yes UV light By Fan Built-in SD card 300 W 340×350×410 mm 18 kg
LNAP-A40 - 24 200 to 10000 µl 10 ml tube strips and magnetic rod’s tip 1 to 24 - Ambient temperature to 120°C Ambient temperature to 120°C 100 copy sample positive rate > 95 % CV < 5 % - Mixing ways can be editable 7-inch touch screen, 3 shortcut buttons and mouse is available - - - Yes - By fan Available with built-in SD card 300 W 560×620×500 mm 54 kg
LNAP-A50 - 96 50 to 1000 µl 96 Deep well plate and 96 magnetic rod’s tip 1 to 96 - Ambient temperature to 120°C Ambient temperature to 120°C 100 copy sample positive rate > 95 % CV < 5 % - Mixing ways can be editable 7-inch touch screen, 3 shortcut buttons and mouse is available - - - Yes - By fan Available with built-in SD card 300 W 560×620×500 mm 54 kg
LNAP-A10 - - - - 1 ~ 20 - - - - CV < 5% - - - - - - Yes - - - - - 28 kgs
LNAP-A11 - - - - 1 ~ 20 - - - - CV < 5% - - - - - - Yes - - - - - 28 kgs
LNAP-A12 - - - - 1 ~ 32 - - - - CV < 5% - - - - - - Yes - - - - - 25 kgs