info@labtron.com +44 2080 043608
Nucleic Acid Purification System LNAP-A50

Nucleic Acid Purification System LNAP-A50

Nucleic Acid Purification System LNAP-A50 is a benchtop unit comes with sample quantity of 96 and process volume of 50 to 1000 µl, offers lysis temperature ranges from ambient temperature to 120°C and elution temperature ranges from ambient temperature to 120°C. Adopted with magnetic bead separation technology, using 96×2.2ml deep well plate and 96 magnetic rod’s tip. Built-in lighting LED lights to observe running status of the instrument in real time, 7 inch touch screen display, exhaust fan and intelligent operation with power protection and self-inspection function. It is suitable to use for large sample size inspection unit and to extract DNA, RNA in 30 to 60 minutes.

Request Quote
Maximum Processing Volume 1ml
Sample Quantity 96
Process Volume 50 to 1000 µl
Consumable 96 Deep well plate and 96 magnetic rod’s tip
Throughput 1 to 96
Working Principle Magnetic beads method
Purification Accuracy 100 copy sample positive rate > 95 %
Stability CV < 5 %
Magnetic Beads Recycling Rate > 95 %
Lysis Temperature Ambient temperature to 120°C
Elution Temperature Ambient temperature to 120°C
Mixing Mixing ways can be editable
Operation Interface 7-inch touch screen, 3 shortcut buttons and mouse is available
Built-In Protocol 8 groups of pre-set protocols, 100 groups of protocols can be stored
Protocol Management New, Edit, Delete, Save as
Expansion Interface Standard USB, Ethernet port and WIFI are available
Lighting Yes
Exhaust Way By fan
Data Storage Available with built-in SD card
Maximum Input Power 300 W
Dimension 560×620×500 mm
Weight 54 kg
  • 7 inch color touch screen display for ease of monitoring various parameters
  • Built in with drip proof plate and automatic identification 8-plate position design
  • Provides program editing, power protection and self-inspection function
  • Adopts lead screw drive, diverse binding and magnetic absorption modes
  • Automatic loading and unloading structure of magnetic rod tip comb
  • Disposable consumables can eliminate the cross contamination between holes and batches
  • To quick stop front cover is opened, convenient for observation and reagent optimization
  • Space saving design with maximum sample size of 10 ml

Nucleic Acid Purification System is widely used in extraction of DNA, RNA and nucleic acid. It is suitable to use in life sciences including biotechnology, microbiology, immunology, cell and molecular biology.

Magnetic Tip Comb
Deep Well Plate
Elution Plate

Compare Models

Model Maximum Processing Volume Sample Quantity Process Volume Consumable Throughput Working Principle Purification Accuracy Stability Magnetic Beads Recycling Rate Lysis Temperature Elution Temperature Mixing Operation Interface Built-In Protocol Protocol Management Expansion Interface Lighting Exhaust Way Data Storage Maximum Input Power Dimension Weight
LNAP-A20 - 10 50 to 1000 µl 5 ml tube strip+ Magnetic rod’s tip 1 to 10 - 100 Copy sample positive rate > 95 % CV < 5 % - Ambient temperature to 120°C Ambient temperature to 120°C Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse - - - Yes By Fan Built-in SD card 300 W 340×350×410 mm 18 kg
LNAP-A21 - 10 50 to 1000 µl 5 ml tube strip+ Magnetic rod’s tip 1 to 10 - 100 Copy sample positive rate > 95 % CV < 5 % - Ambient temperature to 120°C Ambient temperature to 120°C Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse - - - Yes By Fan Built-in SD card 350 W 340×350×410 mm 18.5 kg
LNAP-A30 1 ml 16 50 to 1000 µl 96 Deep well plate and Magnetic rod’s tip 1 to 16 - - CV < 5 % - Ambient temperature to 120°C Ambient temperature to 120°C Mixing methods is editable according to different requirements 4.3 inch touch screen, 3 shortcut keys, external mouse - - - Yes By Fan Built-in SD card 300 W 340×350×410 mm 18 kg
LNAP-A40 10 ml 24 200 to 10000 µl 10 ml tube strips and magnetic rod’s tip 1 to 24 Magnetic beads method 100 copy sample positive rate > 95 % CV < 5 % > 95 % Ambient temperature to 120°C Ambient temperature to 120°C Mixing ways can be editable 7-inch touch screen, 3 shortcut buttons and mouse is available 8 groups of pre-set protocols, 100 groups of protocols can be stored New, Edit, Delete, Save as Standard USB, Ethernet port and WIFI are available Yes By fan Available with built-in SD card 300 W 560×620×500 mm 54 kg
LNAP-A50 1ml 96 50 to 1000 µl 96 Deep well plate and 96 magnetic rod’s tip 1 to 96 Magnetic beads method 100 copy sample positive rate > 95 % CV < 5 % > 95 % Ambient temperature to 120°C Ambient temperature to 120°C Mixing ways can be editable 7-inch touch screen, 3 shortcut buttons and mouse is available 8 groups of pre-set protocols, 100 groups of protocols can be stored New, Edit, Delete, Save as Standard USB, Ethernet port and WIFI are available Yes By fan Available with built-in SD card 300 W 560×620×500 mm 54 kg
LNAP-A10 - - - - 1 ~ 20 - - CV < 5% - - - - - - - - Yes - - - - 28 kgs
LNAP-A11 - - - - 1 ~ 20 - - CV < 5% - - - - - - - - Yes - - - - 28 kgs
LNAP-A12 - - - - 1 ~ 32 - - CV < 5% - - - - - - - - Yes - - - - 25 kgs

Most Viewed