info@labtron.com +44 2080 043608
Plasma Autoclave LPA-C10

Plasma Autoclave LPA-C10

Plasma Autoclave LPA-C10 Functions through an advanced sterilization technique. Boasting a capacity of 120L, and 50 ℃ ± 5 sterilization temperature ensuring compatibility with delicate and heat-sensitive materials. Constructed with 304 stainless steels for longer service life. Our Autoclave ensures fully independent temperature control, excellent thermal conductivity, and uniform temperature distribution.

Request Quote
Capacity 120L
Sterilization Temperature 50 ℃ ± 5
Working Pressure 100 pa
Sterilizing Agent 58 % (H₂O₂) hydrogen peroxide
Sterilizing Time Rapid sterilization time: 25min;
standard sterilization time: 35min;
enhanced sterilization time: 55min
Micro Printer Print multiple records, record sterilization parameters
Sterilization Record 8000 times
RF Power Source Frequency: 50 KHz
Maximum Power: 500W
Heating Power 1800w
Power 380v 3.8KVA
Power Supply 380V, 50 Hz
Internal Dimension (L × W × H) 710 × 480 × 380 mm
External Dimension (L × W × H) 860 × 790 × 1600 mm
Weight 288 kgs
  • Advanced foot-sensing door-opening system
  • Relies on hydrogen peroxide plasma, eliminating the need for harsh chemicals
  • Offers mechanical anti-pinch design ensures precise control without error
  • Comes with a 7-inch high-resolution color touchscreen
  • Equipped with sterilizing filter
  • Incorporates an oil mist filtration system for exhaust
  • Includes dual protective measures in the inner tank for safety and efficiency
  • Incorporated an alarm system for real-time monitoring
  • Leaves no toxic or detrimental residue behind, ensuring the safety of sterilized items

Plasma Autoclave is used in healthcare, laboratories, and various industries to eliminate pathogens from equipment, surfaces, and even delicate instruments that are sensitive to heat and moisture.

PLC Control System


Pressure Transmitter
Vacuum Solenoid Valve
Solenoid Vacuum with Charging Valve
Filter
Precision Filter
Temperature Sensor
Relay
Vacuum Pump
High Voltage Power Supply

Compare Models

Model Capacity Sterilization Temperature Working Pressure Sterilizing Agent Sterilizing Time Micro Printer Sterilization Record RF Power Source Heating Power Power Power Supply Internal Dimension (L × W × H) External Dimension (L × W × H) Weight
LPA-A10 80 L - - - - - - - - - - - - -
LPA-A11 120 L - - - - - - - - - - - - -
LPA-A12 240 L - - - - - - - - - - - - -
LPA-B10 - - - - - - - - - 3.95 kW - - - -
LPA-B11 - - - - - - - - - 4.35 kW - - - -
LPA-B12 - - - - - - - - - 5.15 kW - - - -
LPA-B30 - - - - - - - - - 2.6 kW - - - -
LPA-C10 120L 50 ℃ ± 5 100 pa 58 % (H₂O₂) hydrogen peroxide Rapid sterilization time: 25min;
standard sterilization time: 35min;
enhanced sterilization time: 55min
Print multiple records, record sterilization parameters 8000 times Frequency: 50 KHz
Maximum Power: 500W
1800w 380v 3.8KVA 380V, 50 Hz 710 × 480 × 380 mm 860 × 790 × 1600 mm 288 kgs
LPA-C11 180L 50℃ ± 5℃ - 58% hydrogen peroxide Rapid sterilization time: 25 minutes
Standard sterilization time: 35 minutes
Enhanced sterilization time: 55 minutes.
- 8000 records Frequency: 19KHz
Maximum Power: 500W
1800W 4.2KVA 380V - - 300 Kg

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608