Plasma Autoclave LPA-C10 Functions through an advanced sterilization technique. Boasting a capacity of 120L, and 50 ℃ ± 5 sterilization temperature ensuring compatibility with delicate and heat-sensitive materials. Constructed with 304 stainless steels for longer service life. Our Autoclave ensures fully independent temperature control, excellent thermal conductivity, and uniform temperature distribution.
Request QuoteCapacity | 120L |
Sterilization Temperature | 50 ℃ ± 5 |
Working Pressure | 100 pa |
Sterilizing Agent | 58 % (H₂O₂) hydrogen peroxide |
Sterilizing Time |
Rapid sterilization time: 25min; standard sterilization time: 35min; enhanced sterilization time: 55min |
Micro Printer | Print multiple records, record sterilization parameters |
Sterilization Record | 8000 times |
RF Power Source |
Frequency: 50 KHz Maximum Power: 500W |
Heating Power | 1800w |
Power | 380v 3.8KVA |
Power Supply | 380V, 50 Hz |
Internal Dimension (L × W × H) | 710 × 480 × 380 mm |
External Dimension (L × W × H) | 860 × 790 × 1600 mm |
Weight | 288 kgs |
Plasma Autoclave is used in healthcare, laboratories, and various industries to eliminate pathogens from equipment, surfaces, and even delicate instruments that are sensitive to heat and moisture.
PLC Control System
Available Range :
Capacity : 80 L Capacity : 120 L Capacity : 240 L Chamber Volume : 100 L Chamber Volume : 130 L Chamber Volume : 220 LRelated Models :
Model | Capacity | Sterilization Temperature | Working Pressure | Sterilizing Agent | Sterilizing Time | Micro Printer | Sterilization Record | RF Power Source | Heating Power | Power | Power Supply | Internal Dimension (L × W × H) | External Dimension (L × W × H) | Weight |
LPA-A10 | 80 L | - | - | - | - | - | - | - | - | - | - | - | - | - |
LPA-A11 | 120 L | - | - | - | - | - | - | - | - | - | - | - | - | - |
LPA-A12 | 240 L | - | - | - | - | - | - | - | - | - | - | - | - | - |
LPA-B10 | - | - | - | - | - | - | - | - | - | 3.95 kW | - | - | - | - |
LPA-B11 | - | - | - | - | - | - | - | - | - | 4.35 kW | - | - | - | - |
LPA-B12 | - | - | - | - | - | - | - | - | - | 5.15 kW | - | - | - | - |
LPA-B30 | - | - | - | - | - | - | - | - | - | 2.6 kW | - | - | - | - |
LPA-C10 | 120L | 50 ℃ ± 5 | 100 pa | 58 % (H₂O₂) hydrogen peroxide |
Rapid sterilization time: 25min; standard sterilization time: 35min; enhanced sterilization time: 55min |
Print multiple records, record sterilization parameters | 8000 times |
Frequency: 50 KHz Maximum Power: 500W |
1800w | 380v 3.8KVA | 380V, 50 Hz | 710 × 480 × 380 mm | 860 × 790 × 1600 mm | 288 kgs |
LPA-C11 | 180L | 50℃ ± 5℃ | - | 58% hydrogen peroxide |
Rapid sterilization time: 25 minutes Standard sterilization time: 35 minutes Enhanced sterilization time: 55 minutes. |
- | 8000 records |
Frequency: 19KHz Maximum Power: 500W |
1800W | 4.2KVA | 380V | - | - | 300 Kg |