Portable pH meter LPRPM-A10 is equipped with amplified pH probe and a built-in temperature sensor to measure pH, mV as well as temperature of the solution. This economic pH meter comes with 2 points push button calibration along with auto-buffer recognition to maintain accuracy of test sample readings. The data hold function freezes current reading for easy observation of the test results. It is in accordance with GLP standards.
Request QuotepH range | (-2.00) to 16.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 2 points |
Calibration solutions | USA (pH 4.01 / 7.00 / 10.01), |
Temperature compensation | 0 to 100 °C, 32 to 212 °F, Manual or Automatic |
mV range | (-1999) to 1999 mV |
mV accuracy | ± 1 mV |
mV resolution | 1 mV |
Temperature measuring range | 0 to 100 °C, 32 to 212 °F |
Temperature accuracy | ± 1 °C |
Temperature resolution | 0.1 °C |
Hold function | Manual |
Storage/memory | Stores up to 50 data sets |
Communication output | USB |
Connector | BNC |
Dimension (L × W × H) | 185 × 88 × 32 mm |
Weight | 300 g |
Battery life | About 150 hours |
Power | 9 V / 800 mA battery |
The portable pH meter has applications in waste water treatment & water management, aquaculture, food & beverage processing, environmental monitoring & research and educational purpose.
pH electrode
Temperature probe
pH buffer solution (pH 4.01 / 7.00 / 10.01)
9V battery
Carrying case
Temperature probe
pH buffer solution (pH 4.01 / 7.00 / 10.01)
Suitable pH electrode
Related Models :
Model | pH range | pH accuracy | pH resolution | Calibration points | Calibration solutions | Temperature compensation | mV range | mV accuracy | mV resolution | Temperature measuring range | Temperature accuracy | Temperature resolution | Hold function | Storage/memory | Communication output | Connector | Dimension (L × W × H) | Weight | Battery life | Power |
LPRPM-A10 | (-2.00) to 16.00 pH | ± 0.01 pH | 0.01 pH | 2 points | USA (pH 4.01 / 7.00 / 10.01), | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | (-1999) to 1999 mV | ± 1 mV | 1 mV | 0 to 100 °C, 32 to 212 °F | ± 1 °C | 0.1 °C | Manual | Stores up to 50 data sets | USB | BNC | 185 × 88 × 32 mm | 300 g | About 150 hours | 9 V / 800 mA battery |
LPRPM-A11 | (-2.00) to 20.00 pH | ± 0.002 pH | 0.1, 0.01, 0.001 pH | 1 - 5 points | USA (pH 4.01 / 7.00 / 10.01 / 12.45), NIST(pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45), DIN (pH 1.09 / 4.65 / 6.79 / 9.23 / 12.75) or user defined | 0 to 100 °C, 32 to 212 °F, Manual or Automatic | (-1999) to 1999 mV | ± 0.2 mV | 0.1, 1 mV | 0 to 100 °C, 32 to 212 °F | ± 0.5 °C, ± 0.9 °F | 0.1 °C | Manual | Stores up to 500 data sets | USB interface | BNC | 170 × 85 × 30 mm | 300 g | About 150 hours | 4.5 V “AA batteries or DC 5 V power adapter |