Flame Photometer LFP-A30 is a benchtop unit that determines concentration of metal ions like K, Na, Li and Ca in a test sample. Designed with 7-inch color touch screen display that displays direct concentration of elements. Equipped with USB interface for data transfer and storage. Features flameout protection device and air compressor. It automatically determines correlation coefficient of test sample.
Request QuoteTesting Elements | K, Na, Li, Ca | ||||||||
No of Channels | 4 | ||||||||
Display Value | Concentration value | ||||||||
Data Range | 0.000 to 999.9 | ||||||||
Range |
|
||||||||
LOD |
|
||||||||
Linear Error |
|
||||||||
Display | 7-inch colour touch screen | ||||||||
Response time | time <8s | ||||||||
Sample uptake | < 6 ml/min | ||||||||
Stability | <3% drift over 15s during continuous aspiration | ||||||||
Reproducibility | <3% coefficient of variation for 7 consecutive samples | ||||||||
Fuel | LPG | ||||||||
Interface | USB | ||||||||
Power supply | AC 220 V±22 V 50 Hz±1 Hz, 250 W | ||||||||
Overall Dimensions | 780 × 560 × 390 mm | ||||||||
Weight | 18 kg |
Flame Photometer has wide applications in areas like clinical laboratories, pathology, research laboratories, soil and fertilizer industries, petroleum and mining industries, chemical product manufacturing units, pharmaceutical and beverage industries.
Model | Testing Elements | No of Channels | Display Value | Data Range | Range | LOD | Linear Error | Display | Response time | Sample uptake | Stability | Reproducibility | Fuel | Interface | Power supply | Overall Dimensions | Weight | ||||||||||||||||||||||||||||||
LFP-A10 | K, Na | 2 | Optical Power | 0000 to 9999 |
|
|
|
7-inch colour touch screen | time <8s | < 6 ml/min | <3% drift over 15s during continuous aspiration | <3% coefficient of variation for 7 consecutive samples | LPG | NA | AC 220 V±22 V 50 Hz±1 Hz, 250 W | 780 × 560 × 390 mm | 18 kg | ||||||||||||||||||||||||||||||
LFP-A11 | K, Na | 2 | Concentration value | 000.0 to 999.9 |
|
|
|
7-inch colour touch screen | time <8s | < 6 ml/min | <3% drift over 15s during continuous aspiration | <3% coefficient of variation for 7 consecutive samples | LPG | USB | AC 220 V±22 V 50 Hz±1 Hz, 250 W | 780 × 560 × 390 mm | 18 kg | ||||||||||||||||||||||||||||||
LFP-A20 | K, Na, Li | 3 | Concentration value | 0.000 to 999.9 |
|
|
|
7-inch colour touch screen | time <8s | < 6 ml/min | <3% drift over 15s during continuous aspiration | <3% coefficient of variation for 7 consecutive samples | LPG | USB | AC 220 V±22 V 50 Hz±1 Hz, 250 W | 780 × 560 × 390 mm | 18 kg | ||||||||||||||||||||||||||||||
LFP-A21 | K, Na, Ca | 3 | Concentration value | 0.000 to 999.9 |
|
|
|
7-inch colour touch screen | time <8s | < 6 ml/min | <3% drift over 15s during continuous aspiration | <3% coefficient of variation for 7 consecutive samples | LPG | USB | AC 220 V±22 V 50 Hz±1 Hz, 250 W | 780 × 560 × 390 mm | 18 kg | ||||||||||||||||||||||||||||||
LFP-A30 | K, Na, Li, Ca | 4 | Concentration value | 0.000 to 999.9 |
|
|
|
7-inch colour touch screen | time <8s | < 6 ml/min | <3% drift over 15s during continuous aspiration | <3% coefficient of variation for 7 consecutive samples | LPG | USB | AC 220 V±22 V 50 Hz±1 Hz, 250 W | 780 × 560 × 390 mm | 18 kg | ||||||||||||||||||||||||||||||
LFP-A40 | K, Na, Li, Ca, Ba | 5 | Concentration value | 0.000 to 999.9 |
|
|
|