info@labtron.com +44 2080 043608
PMCC Flash Point Tester LCFP-A10

PMCC Flash Point Tester LCFP-A10

LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.

Request Quote
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Standard oil cup-Inner diameter 50.7 ~ 50.8 mm
Standard oil cup- Depth 55.7 ~ 56.0 mm
Standard oil cup- Depth of Marked line on the oil cup 33.9 ~ 34.3 mm
Standard oil cup-Oil sample cubage About 70 ml
Stirring speed 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B
Stirring blade 8 × 40 mm
Sample temperature rising rate 1 ~ 12 °C per minute
Heating power 0 ~ 600 W
Dimension 420 × 350 × 350 mm
Total Power Consumption 600 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Ignition source : Coal gas Rod type Mercury Thermometer Variable Temperature Range 45TYZ Stirring Motor

It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C

Compare Models

Model Ambient temperature Relative humidity Ignition Mode Temperature range Aperture of ignition device Standard oil cup-Inner diameter Standard oil cup- Depth Standard oil cup- Depth of Marked line on the oil cup Standard oil cup-Oil sample cubage Stirring speed Stirring blade Sample temperature rising rate Measurement Range Flash Point Resolution Repeatability Reproducibility Accuracy Precision Gas Flame Heating power Dimension Total Power Consumption Power supply Net Weight
LCFP-A10 ≤ 35 °C ≤ 85 % - 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C 0.8 mm 50.7 ~ 50.8 mm 55.7 ~ 56.0 mm 33.9 ~ 34.3 mm About 70 ml 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B 8 × 40 mm 1 ~ 12 °C per minute - - - - - - - - 0 ~ 600 W 420 × 350 × 350 mm 600 W AC 220 V ± 10 %, 50 Hz -
LCFP-A11 10 °C ~ 40 °C ≤ 80 % - - - - - - - - - - Ambient Temperature ~ 250 °C Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C 0.1 °C - - - 0.005 3 ~ 4 mm - 550 × 470 × 500 mm 350 W AC 220 V ± 10 %, 50 Hz -
LCFP-A14 - - - - - - - - - - - - - - - - - - - - - 730 × 530 ×5 80mm ≤ 5400W - -
LCFP-A12 - - - - - - - - - - - - - - - - - 0.1℃ - - - 510 ×320 × 330mm - - -
LCFP-A13 - - Electric Ignition - - - - - - - - - 40 ℃ to 350 ℃ - - 110℃ ±2℃ (>110℃)
110℃±1℃ (<110℃)
- - - - - 500 × 400 × 380 mm - - -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.