info@labtron.com +44 2080 043608

Petroleum Testing Equipment

LABC-A10 Automatic Bomb Calorimeter LABC-A10

Calorimeter type : Isoperibol

Temperature range : 5 to 40°C

Measurement range : 5 to 40 MJ/ kg

Operation Mode : The outer barrel temperature is constant

LABC-A11 Automatic Bomb Calorimeter LABC-A11

Calorimeter type : Isoperibol

Temperature range : 5 to 40°C

Measurement range : 5 to 40 MJ/ kg

Operation Mode : A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode

LABC-B10 Automatic Bomb Calorimeter LABC-B10

Calorimeter type : Isoperibol

Oxygen filling : Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering

Bomb volume : 250 ml

Analysis time : < 8 min full test process:

LABC-B11 Automatic Bomb Calorimeter LABC-B11

Calorimeter type : Isoperibol

Oxygen filling : Semi-automatic

Bomb volume : 282 ml

Analysis time : 15 to 25 min

LOCT-A10 Octane & Cetane Analyzer LOCT-A10

Test Liquids : Diesel, Gasoline

Measuring Range for Gasoline : Aviation gasoline: 86.0 to 105.0/MON Automobile gasoline: 50.0 to 115.0/RON

Measuring Range for Diesel : Automobile diesel oil: 25 to 75/CN

Measuring Accuracy : Aviation gasoline: ≤ ± 1.5/MON Automobile gasoline: ≤ ± 1.5/RON, ≤ ± 1.5/MON Automobile diesel oil: ≤ ± 2.5/CN, ≤ ± 2.5/CI Retest of regression samples: ≤ ± 0.5/RON, ≤ ± 0.5/MON Test of regression sample: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON

LOCT-A20 Octane & Cetane Analyzer LOCT-A20

Measurement item : motor gasoline and diesel

measurement unit of octane is ON : 40 to 120

Permissible error of octane : ± 0.5 max

Fluctuate range of octane : ± 0.2 max

LOCT-B10 Octane & Cetane Analyzer LOCT-B10

Octane number range : 40 to 125 ON

Maximum error limit octane number : ±0.5 ON

Maximum parallel ON difference : ±0.2

Antiknock range : 0.5 to 15 %

LAAT-A11 Acid Number and Acidity Tester LAAT-A11

Ambient temperature : ≤ 35 °C

Relative humidity : ≤ 85 %

Precision of titration tube : Scale division is 0.02 ml

Total power consumption : ≤ 1200 W

LAAT-A12 Acid Number Tester LAAT-A12

Measurement range : ≥0.05 mg KOH/g

Potential measurement range : 0 to 1800.0 mV

Burette volume : 10 mL

Minimum titration volume : 0.001 ml

LAAT-A13 Base Number Tester LAAT-A13

Volumetric analysis : Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml

Automatic acid titration : Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH

Automatic potential control : Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV

Ambient temperature : 0 ~ 35 ℃

LAAT-A10 Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask : 100 ml,50 ml

Conical flask : 100ml

Separatory funnel : 250ml

Ambient temperature : (-10 )°C to 35 °C

LAPT-A10 Aniline Point Tester LAPT-A10

Measurement range : Room temperature ~ 150°C

Stirring speed : 0 ~ 1200 r / min

Heating power : 25 W

Interior Dimension : 360 × 250 × 545 mm

LAPT-A11 Aniline Point Tester LAPT-A11

Temperature controlling accuracy : ≤ 0.5 ℃

Temperature controlling range : Room temperature ~ 200 ℃

Power supply for illumination : 5 V

Power of motor : 2 kW

LCFP-A11 Automatic PMCC Flash Point Tester LCFP-A11

Ambient temperature : 10 °C ~ 40 °C

Relative humidity : ≤ 80 %

Measurement Range : Ambient Temperature ~ 250 °C

Flash Point : Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C

LCFP-A12 Automatic PMCC Flash Point Tester LCFP-A12

Flash Point Determination Range : Ambient to 230℃

Accuracy : 0.1℃

Heating Rate : Procedure A: (5 to 6)℃/min Procedure B: (1 to 1.5)℃/min Procedure C: (3.0±0.5)℃/min

Stirring Rate : Procedure A and C: (90 to 120)RPM Procedure B: (250±10)RPM Automatic control and manually adjustable

LCFP-A13 Automatic PMCC Flash Point Tester LCFP-A13

Ambient Temperature : 10 ℃ to 35 ℃

Relative Humidity : < 85%

Ignition Mode : Electric Ignition

Cooling Method : Forced Air Cooling

LCFP-A14 Automatic PMCC Flash Point Tester LCFP-A14

Temperature Range : 0 ℃ to 60 ℃

Temperature Accuracy : ±0.5℃

Ambient Temperature : 15℃ to 35℃

Relative Humidity : ≤ 85%

LCFP-A10 PMCC Flash Point Tester LCFP-A10

Ambient temperature : ≤ 35 °C

Relative humidity : ≤ 85 %

Temperature range : 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C

Aperture of ignition device : 0.8 mm

LDCT-A10 Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

Ambient temperature : Room temperature to 35 °C

Relative humidity : ≤ 85 %

Timing range : 1 s to 9 min 59 s

Temperature controlling range : Room temperature to 99.9 °C

LDCT-A11 Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Ambient temperature : Room temperature to 35 °C

Relative humidity : ≤ 85 %

Temperature controlling range : Room temperature to 99.9 °C

Temperature controlling accuracy : ± 1 °C

LDMT-A10 Density Tester LDMT-A10

Cubage of bath : Ф300 × 380 mm

Temperature controlling range : 0 °C ~ 100 °C

Temperature controlling accuracy : ± 0.2 °C

Temperature sensor : Industrial platinum resistance, Pt100

LADA-A10 Automatic Distillation Apparatus LADA-A10

Heating power : 2 kW

Cooling power : 0.5 kW

Steam temperature : 0 to 400℃

Oven temperature : 0 to 500℃

LDT-A11 Benzene Distillation Tester (Low Temperature) LDT-A11

Ambient temperature : -10°C to 35°C

Relative humidity : ≤ 85 %

Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C

Scale division : 0.1 ℃

LDT-A16 Distillation Tester (low temperature Double units) LDT-A16

Graduated flasks : 100 ml

Distillation flask : 125 ml

Ambient temperature : ≤ 35 °C

Relative humidity : ≤ 85 %

LDT-A17 Distillation Tester (low temperature single unit) LDT-A17

Graduated flasks : 100 ml

Distillation flask : 125 mL

Ambient temperature : ≤ 30 °C

Relative humidity : ≤ 85 %

LDT-A15 Distillation Tester Dual Units LDT-A15

Graduated flasks : 100 ml

Scale division of graduated flask : 1ml

Distillation flask : 125 ml

Ambient temperature : ≤ 35 °C

LDT-A14 Distillation Tester Front Type LDT-A14

Distillation flask : 125 mL

Ambient temperature : Room temperature to 35 °C

Relative humidity : ≤ 85 %

Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃

LDT-A10 Distillation Tester LDT-A10

Graduated flasks : 10 ml and 100 ml

Scale division of graduated flask : 10 ml is 0.1 ml and 100 ml is 1 ml

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

LDT-A12 Distillation Tester LDT-A12

Graduated flasks : 100 ml

Scale division of graduated flask : 1 ml

Outer diameter of distillation flask : φ65

Refrigeration tube : φ14

LDT-A13 Vacuum Distillation Tester LDT-A13

Ambient temperature : 5 °C to 35 ℃

Relative humidity : ≤ 85 %

Cubage of buffer vessel : 1000 ml

Max. Residual pressure : ≤ 2 mm Hg

LDT-A18 Vacuum Distillation Tester LDT-A18

Evaporation tube specifications : 200 Φ mm

Evaporation tube heat transfer area : 0.4 m2

Built-in cooling area : 0.5 m2

Constant pressure feeding bottle : 3 L

LDPT-A11 Dropping Point Tester (Air bath) LDPT-A11

Ambient temperature : ≤ 35 ℃

Relative humidity : ≤ 85 %

Heating power of electric furnace : 250 W × 2

Total power consumption : ≤ 700 W

LDPT-A10 Dropping Point Tester (Oil Bath) LDPT-A10

Beaker quantity : 600 ml

Ambient temperature : (-10) °C ~ 40 °C

Relative humidity : ≤ 85 %

Thermometer Measurement range : (-5) °C ~ 300 °C

LEV-A10 Engler Viscometer LEV-A10

Graduated Flask : 200 ± 0.2 ml

Standard Water Value : 51 ± 1 s

Temperature Range : 0 ~ 100 °C

Temperature Controlling Accuracy : ± 0.2 °C

LEV-A11 Engler Viscometer LEV-A11

Graduated Flask : 100 ml

Standard Water Value : 51 ± 1 s

Temperature Range : 0 ~ 100 °C

Temperature Controlling Accuracy : ± 0.1 °C

LEV-B10 Engler Viscometer LEV-B10

Graduated Flask : 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)

Standard Water Value : 51 ± 1 s

Temperature Range : 0 ~ 100 °C

Ambient Temperature : 10 °C ~ 40 °C

LEGT-B30 Existent Gum Tester LEGT- B30

Bath type : Oil bath

Bath capacity : 5000 ml ± 50 ml

Ambient temperature : Room temperature to 35 °C

Relative humidity : ≤ 85 %

LEGT-B31 Existent Gum Tester LEGT- B31

Evaporation bath type and size : Aluminum block bath, φ260 × 130 mm

Holes for testing : 3 pieces

Size of holes for testing cylinder : φ51 × 70 mm

Flow rate display : Flow meter

LEGT-B32 Existent Gum Tester LEGT- B32

Evaporation bath type and size : Aluminum bath φ260 × 130 mm

Holes for testing : 5 pieces

Size of holes for testing cylinder : φ51 × 70 mm

Working temperature : 160 ℃ ~ 165℃

LKV-A10 Kinematic Viscometer LKV-A10

Ambient temperature : 15 to 35°C

Relative humidity : ≤ 85%

Capillary viscometer : 6 capillary Pinkevitch viscometer tubes

Stirring motor : 1200 rpm

LKV-A11 Kinematic Viscometer LKV-A11

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Stirring motor : 6 W, 1200 rpm

LKV-A12 Kinematic Viscometer LKV-A12

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Stirring motor : 6 W, 1200 rpm

LKV-A13 Kinematic Viscometer LKV-A13

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group

Stirring motor : 6 W, 1200 rpm

LKV-A15 Kinematic Viscometer LKV-A15

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Stirring motor : 6 W, 1200 rpm

LKV-A16 Kinematic Viscometer LKV-A16

Ambient temperature : 0 ~ 40 ºC

Relative humidity : 20 ~ 90 %, RH while 40 ℃

Temperature controlling accuracy : ± 0.1 °C

Timing range : 0.0 s ~ 9999.9 s

LKV-A14 Low Temperature Kinematic Viscosity Tester LKV-A14

Ambient temperature : ≤ 30 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 13 pieces

Stirring motor : 6 W, 1200 rpm

LLTT-A23 Automatic Pour Point Tester LLTT-A23

Ambient temperature : ≤ 30 ℃

Refrigeration speed : > 40 °C / 10 min

Repeatability for solidifying point : ≤ 2 °C

Repeatability for pour point : ≤ 3 °C

LLTT-A12 Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Ambient temperature : (-10)℃ ~ 35 ℃

Relative humidity : ≤ 85 %

Sample cup Inner diameter : 31.0 ~ 32.0 mm

Sample cup Wall thickness : 1.0 ~ 1.5 mm

LLTT-A11 Freezing Point Tester LLTT-A11

Freezing Point Range : -54℃ to 2℃

Cold Bath Temperature Range : -70℃ to 30℃

Temperature Accuracy : ±0.1℃

Refrigerator System : Imported Refrigerator Compressor

LLTT-A16 Multifunctional Low Temperature Tester LLTT-A16

Refrigeration system : New-type refrigeration compressor

Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C

Ambient temperature : ≤ 30 ℃

Relative humidity : ≤ 85 %

LLTT-A14 Pour and Cloud Point Tester LLTT-A14

Chamber quantity : 2 chambers

Chamber 01 temperature control : Ambient to -51 ℃

Chamber 02 temperature control : Ambient to -65 ℃

Temperature precision : ±1°C

LLTT-A15 Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Refrigeration system : New-type refrigeration compressor

Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C

Ambient temperature : ≤ 30 ℃

Relative humidity : ≤ 85 %

LLTT-A10 Solidifying Point Constant Temperature Water Bath LLTT-A10

Capacity : 20 L

Temperature range : Ambient +5°C to 100°C

Precision : ± 0.1℃

Stirring range : 1200 r/min

LLTT-A22 Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Temperature controlling accuracy : ± 0.5 °C

Refrigeration system : New-type refrigeration compressor

Cold trough : One trough with two baths, temperatures in two baths are equal

Controlling temperature of cold trough : Room temperature ~ (-70) °C

LLTT-A21 Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

Refrigeration system : New-type refrigeration compressor

Cold trough : One trough with two baths, temperatures in two baths are equal

Controlling temperature of cold trough : Room temperature ~ (-70) °C

Ambient temperature : ≤ 30 ℃

LLTT-A13 Solidifying Point Tester LLTT-A13

Temperature controlling accuracy : ± 0.5 ℃

Refrigeration system : New-type refrigeration compressor

Cold trough : Two holes in one trough, and same temperature

Ambient temperature : ≤ 30 ℃

LLTT-A20 Solidifying Point Tester LLTT-A20

Temperature controlling accuracy : ± 0.5 °C

Refrigeration system : New-type refrigeration compressor

Cold trough : One trough with two baths, temperatures in two baths are equal

Controlling temperature of cold trough : Room temperature ~ (-70) °C

LOFP-A12 Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Ambient Temperature : 10 ℃ ~ 40 °C

Relative Humidity : ≤ 80 %

Temperature Measurement- Full Scale : Ambient temperature to 300 °C

Temperature Measurement- Repeatability : ≤ 8 °C

LOFP-B10 Automatic COC Flash & Fire Point Tester LOFP-B10

Ambient Temperature : 10 ℃ ~ 40 ℃

Relative Humidity : ≤ 85 %

Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃

Temperature Measurement- Repeatability : ≤ 4 ℃

LOFP-A11 Cleveland Open Cup Flash Point Tester LOFP-A11

Thermometer : 6 ℃ ~ 400 ℃

Scale Division : 2 °C

Spout Aperture : 0.6 ~ 0.8 mm

Ambient Temperature : -10 ℃ ~ 50 ℃

LOFP-A10 Open Cup Flash Point Tester LOFP-A10

Thermometer : 0 ℃ ~ 360 °C

Scale Division : 1 °C

Ambient Temperature : ≤ 35 °C

Relative Humidity : ≤ 85 %

LOST-D10 Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Samples : 2

Oil bath cubage : 30 L

Angle between bomb and water surface : 30 °

Speed of rotary assembly : 100 ± 5 RPM

LOST-D14 Biodiesel Oxidation Stability Tester LOST-D14

Temperature Range : RT to 150 ℃

Temperature Accuracy : ±0.1℃

Temperature Control : PID digital display temperature controller

Sample Volume : 5 g

LOST-D12 Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Samples : 8

Temperature : 100 ℃

Temperature controlling accuracy : 0.1 ℃

Flow meter : 3 ± 0.3 L / H oxygen

LOST-D13 Gasoline Oxidation Stability Tester LOST-D13

Type : Compact; Desktop

Design : Integrated

Bath : Metal bath (without water usage)

Temperature control point of metal bath : 100℃ ± 1℃

LOST-D20 Oxidation Stability Tester (Lubricating Grease) LOST-D20

Temperature Range : Ambient to 150℃

Temperature Precision : ± 0.1°C

Test Unit : 2 units

Heating Power : 1800 W

LOST-D11 Transformer Oil Oxidation Stability Tester LOST-D11

Samples : 6

Temperature controlling mode : Automatic digital temperature

Temperature controlling range : Room temperature ~ 160 °C

Temperature controlling accuracy : ± 0.2 °C

LBC-C20 Oxygen Bomb Calorimeter LBC-C20

Heat capacity : 14000 ~ 15000 J / K

Temperature measurement range : 10 ~ 35 ℃

Repeatability error : ≤ 0.2 % (Grade C)

Endured pressure in oxygen bomb : 20 MPa

LBC-C21 Oxygen Bomb Calorimeter LBC-C21

Temperature controlling range : 10 ℃ ~ 35 ℃

Temperature resolution : 0.001 ℃

Mean value of heat capacity : 15 kJ / K

Ambient temperature : 20 ℃ ± 5 ℃

LBC-C22 Oxygen Bomb Calorimeter LBC-C22

Temperature measurement range : 10 ~ 35 ℃

Repeatability error : ≤ 0.2 % (Grade C)

Endured pressure in oxygen bomb : 20 MPa

Operation environment temperature : 15 ~ 28 ℃

LRCT-B10 Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Porcelain crucible : 30 ml

Inner iron crucible : 75 ml

Outer iron crucible : 190 ml

Burner : Mig Burner

LRCT-B11 Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

Bath type : Four holes with a furnace

Heating type : Electric resistance furnace

Temperature controlling range : 0 ~ 520 °C

Temperature controlling accuracy : ± 5 °C

LRCT-B20 Carbon Residue Tester (Ramsbottom) LRCT-B20

Coking furnace : Metal furnace

Heating mode : Electric heating

Test unit : 5 units

Temperature range : Ambient to 550°C

LRCT-A13 Copper Strip Corrosion Tester LRCT-A13

Sample hole : 4 pieces

Sample quantity : 4 to 12 pieces

Ambient temperature : Room temperature to 35 °C

Temperature controlling range : Room temperature to 100°C

LRCT-A10 Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Sample hole : 2 pieces

Speed of stirring motor : 1400 rpm

Ambient temperature : 10 to 35°C

Temperature controlling range : Room Temperature to 100°C

LRCT-A11 Lubricating Oil Rust Characteristics Tester LRCT-A11

Sample hole : 4 pieces

Speed of stirring motor : 1400 rpm

Speed for sample stirring : 1000 ± 50 rpm

Ambient temperature : Room temperature to 35°C

LRCT-A12 Rust Characteristics and Corrosion Tester LRCT-A12

Sample hole : 4 pieces

Ambient temperature : Room temperature to 35°C

Temperature controlling range : 0 to 100°C

Temperature controlling accuracy : ± 1°C

LST-A11 Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

Air flow rate : Not less than 150 L / h

Max. Preset time : 99 min 59 s (100 min)

Chamber diameter of oven : Φ22 mm

Heating power of oven : 1400 W × 2

LST-A10 X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

Sample quantity : 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)

Measurement time : 60, 120, 240, 300, and 600 s at random

Measurement range : 7 ppm to 5 %

Repeatability : < 0.029 (S + 0.6)

LVPT-C11 Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Test bomb : Two samples or a group of parallel samples

Bath temperature : 37.8 °C

Temperature controlling accuracy : 0.1 °C

Dimensions : 500 × 560 × 680 mm, 950 × 540 × 720 mm

LVPT-C10 Vapor Pressure Tester (REID METHOD) LVPT-C10

Operation temperature of water bath : RT ~ 90 °C

Temperature controlling accuracy : ± 0.1 °C

Dimensions : 550 × 520 × 102 mm

Pressure meter accuracy : ± 0.4 % kPa

LWT-A30 Coulometric Karl Fischer Titrator LWT-A30

Ambient Temperature : 10°C to 35°C

Measurement Range : 0 to 100 mg

Resolution : 0.1 µg

Max. Electrolysis Speed : 40 µg /s

LWT-A31 Coulometric Karl Fischer Titrator LWT-A31

Maximum current : 400 mA

Measurement range : 3 µg to 9999.9 µg

Resolution : 0.1 µg

Precision 1 : ± 2 µg (3µg H2O to 20µg H2O)

LWT-A32 Coulometric Karl Fischer Titrator LWT-A32

Measurement Range : 1 µg to 200 mg

Electrolytic Current Control : 0 to 400 mA

Sensitive Valve : 0.1 µg H2O

Accuracy : 10µg to 1000μg, ±3μg More than 1mg but not greater than 0.3%

LWT-B10 Crude Petroleum Water Content Tester LWT-B10

Ambient Temperature Range : -10 to 35°C

Relative Humidity : ≤85%

Distillation Flask : 1000 ml

Receiver : 5 ml, with 0.05 ml graduation

LWT-A20 Volumetric Karl Fischer Titrator LWT-A20

Measuring range : 30 ppm to 100%

Resolution : 0.01 ml

Repeatability : ˂ 0.01

Moisture display resolution : 1 ppm

LWT-A21 Volumetric Karl Fischer Titrator LWT-A21

Measuring range : 10 ppm to 100%

Resolution : 0.001 ml

Repeatability : ≤ 0.005

Moisture display resolution : 1 ppm

LWT-A10 Water Content Tester LWT-A10

Ambient Temperature Range : ≤ 35°C

Relative Humidity : ≤ 85%

Heating Mantle Cap Power : 1000 W

Sample Determination : 1 at a time

LWT-A11 Water Content Tester LWT-A11

Ambient Temperature Range : ≤ 35°C

Relative Humidity : ≤ 85%

Heating Mantle Cap Power : 1000 W × 2

Sample Determination : 2 at a time

LACF-A10 Automatic Tag Closed Flash Point Tester LACF-A10

Experimental temperature range : -50 to 70°C

Test sample volume : 50 ml

Ambient temperature range : 10 to 40°C

Humidity : ≤ 85%

LSGT-A10 Specific Gravity Tester LSGT-A10

Vessel Volume :  4000 ml × 2

Power of Vacuum pump : 160 W

Negative power : 3.7 kPa(27.75 mmHg)

Power of shaking machine : 30 W

LADT-A10 Automatic Dielectric Tester LADT-A10

Capacity : 2.0 kVA

Speed of voltage increase : 2 k V/ s

Voltage inspection accuracy : 0.01

Breakdown sensitivity : < 0.1 kV

LSPT-A10 Automatic Softening Point Tester LSPT-A10

Measurement range : 32 ℃ to 160 ℃

Ambient temperature : 35 °C

Temperature resolution : 0.01 ℃

Beaker volume : 1000 mL

LTGA-A10 Automatic Thermogravimetric Analyzer LTGA-A10

 Temperature range : Room temperature to 1000 ºC

Temperature resolution : 0.1 ºC

Temperature fluctuation : ±0.1 ºC

Heating rate : 1 ~ 80 ºC / min

LTGA-A11 Automatic Thermogravimetric Analyzer LTGA-A11

Temperature Range : Room temperature to 1600℃

Temperature Resolution : 0.01℃

Temperature Fluctuation : ±0.1℃

Heating Rate : 0.1 to 100℃/min

LMPT-A10 Penetrometer LMPT-A10

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec

Time accuracy : ± 0.1 seconds

Resolution : 0.01 mm

LMPT-A11 Penetrometer LMPT-A11

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec or 60 sec

Time accuracy : ± 0.1 seconds

Resolution : 0.01 mm

LMPT-A13 Penetrometer LMPT-A13

Measurement range : 0 to 600 penetration scale

Timing range : 0 sec to 60 sec

Time accuracy error : ≥ ± 0.1 seconds

Resolution : 0.1 penetration

LFCT-A10 Foaming Characteristics Tester LFCT-A10

Temperature Range : Ambient to 100°C

Temperature Precision : ± 0.1°C

Air Flow : 94 mL ± 5 mL/min, with flowmeters

Timing Unit : 0 to 99 min 59 s, resolution 1 s

LMST-A10 Mercaptan Sulfur Tester LMST-A10

Potential measuring range : (0 to ±1999.5) Mv

Intrinsic error : 0.1 % ±0.5 mV

Input impedance : Ri ≥1 × 1012 Ω

Burette capacity : 10 mL

LTNP-A10 Constant Temperature Needle Penetration Tester LTNP-A10

Measuring range : 0 to 700 taper degree (digital display table 0-70 mm)

Timing device : Timing error is less than ±0.1 s

 Resolution : 0.01 mm

Needle insertion accuracy : ±1 cone insertion degree

LCOS-A10 Automatic Crude Oil Salt Content Analyzer LCOS-A10

Measuring range : Temperature: -5.0°C to 105.0°C pH: 0.00 to 14.00 mV: -1800 to 1800

Resolution : Temperature: 0.1°C pH: 0.01 mV: 0.1

Basic error : Temperature: ±0.3°C ± 1 word pH: ±0.01 ± 1 word mV: ±0.03% FS

Control temperature : 60°C ±1°C

LOSA-A10 Oil Separation Apparatus LOSA-A10

Test unit : 2

Sieve aperture : 75 µm

Pressure display : Precision digital pressure gauge

Cooling method : Totally enclosed compressor cooling

LMIT-A21 Mechanical Impurity Tester (Weight Method) LMIT-A21

Dimension : 390 x 260 x 590 mm

Total power consumption : ≤ 1200 W

Power supply : AC 220 V ± 10 %, 50 Hz

Heating power of water bath : 1000 W

LWCT-A22 Wax Oil Content Tester LWCT-A22

Power supply : AC 220 V ± 10 %, 50 Hz

Temperature controlling range in water bath : RT ~ 90 ℃ ± 5 ℃

Cooling bath temperature : (-35) ℃ ± 1 ℃

Evaporation temperature : 35 ℃ ± 1 ℃

LIBT-A23 Oil Breakdown Voltage Tester LIBT-A23

Power supply : AC 220 V ± 5 % , 50Hz

Measurement range : 0 ~ 75 kV

Voltage rising rate : 3 kV ± 10 % / s

Distance between electrodes : 2.5 mm

LCT-A20 Color Tester LCT-A20

Light source : 220 V, 100 W

Temperature of grinding milk white light bulb : 2750 ± 50 K

Light hole( Φ14) : 26 pieces

Color comparing tube : Φ32 mm

Download catalog

Aniline Test Equipment
Demulsibility Characteristics Tester
Density Tester
Dropping Point Tester
Oxygen Bomb Calorimeter
Sulphur Content Tester
Automatic Tag Closed Flash Point Tester
Specific Gravity Tester
Automatic Dielectric Tester
Automatic Softening Point Tester
Automatic Thermogravimetric Analyzer
Foam Testing Equipment
Ash Content Tester
Mercaptan Sulfur Tester
Constant Temperature Needle Penetration Tester
Crude Oil Salt Content Analyzer
Oil Separation Apparatus
Mechanical Impurity Tester
Wax Oil Content Tester
Oil Breakdown Voltage Tester
Color Tester

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.