Labtron LKV-A11 Kinematic Viscometer is used for precise measurement with capillary viscometers. It is made according to “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity” as per ASTM D445.
Request QuoteAmbient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Temperature controlling accuracy | ± 0.1 °C |
Constant temperature bath | 20 L; two layers water bath |
Temperature sensor | Industrial platinum resistance; Pt100 |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional) |
It is used in the fields of petroleum & its products industries, research and development department.
Model | Ambient temperature | Relative humidity | Capillary viscometer | Stirring motor | Sample quantity | Bath temperature | Measurement range | Bath cubage | Temperature controlling range | Temperature controlling accuracy | Illumination | Constant temperature bath | Timing range | Barometric | Timing accuracy | Timing device | Temperature sensor | Inner capillary viscometer diameters | Mercury thermometer scale division |
LKV-A10 | 15 to 35°C | ≤ 85% | 6 capillary Pinkevitch viscometer tubes | 1200 rpm | - | - | - | - | - | - | - | - | - | - | - | - | RTD PT100 | - | - |
LKV-A11 | (-10) °C ~ 35 °C | ≤ 85 % | 11 pieces | 6 W, 1200 rpm | - | - | - | - | - | ± 0.1 °C | - | 20 L; two layers water bath | - | - | - | - | Industrial platinum resistance; Pt100 | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional) | - |
LKV-A12 | (-10) °C ~ 35 °C | ≤ 85 % | 11 pieces | 6 W, 1200 rpm | - | - | - | - | Ambient temperature ~ 100 °C | ± 0.1 °C | - | 20 L, two layer bath | - | - | - | 0.1 s ~ 999.9 s, resolution is 0.1 s | - | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively | - |
LKV-A13 | (-10) °C ~ 35 °C | ≤ 85 % | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group | 6 W, 1200 rpm | 3 piece at the same time | Ambient temperature ~ 180.0 °C | 100 ~ 150 °C or 150 ~ 200 °C | 23 L | - | ± 0.1 °C | - | - | - | - | - | - | - | 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm | 0.1 °C |
LKV-A14 | ≤ 30 °C | ≤ 85 % | 13 pieces | 6 W, 1200 rpm | - | - | - | - | Ambient temperature ~ 70 °C | ± 0.1 °C | 6 W / 220 V fluorescent lamp | 5.8 L with stainless steel inner tank | - | - | - | - | - | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 mm | - |
LKV-A15 | (-10) °C ~ 35 °C | ≤ 85 % | 11 pieces | 6 W, 1200 rpm | 4 piece at the same time | - | Ambient Temperature ~ 100.0 °C | 20 L | - | ± 0.1 °C | - | - | 0.0 s ~ 9999.9 s | - | ≤ ± 0.05 % in 60 min | - | - | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 mm | - |
LKV-A16 | 0 ~ 40 ºC | 20 ~ 90 %, RH while 40 ℃ | - | - | - | - | - | - | - | ± 0.1 °C | - | - | 0.0 s ~ 9999.9 s | 96 ~ 103 kPa | ± 0.1 s | - | - | - | - |