Crush tester TP-L10 is adopted with advanced parts, microprocessor controlled system and multifunctional design to test, translate, adjust, display, remember, and print the test data. User can conduct any test of choice like TCT, FCT, ECT, and PAT for paper and cardboard material by selecting additional, corresponding accessories.
Request QuoteMeasurement range | 5 to 500 N, 50 to 3000 N |
Resolution | 1 N |
Accuracy | ± 1 % |
Variability | ≤ 1 % |
Speed | 12.5 ± 2.5 mm/min |
Maximum distance | 78 mm |
Dimension (L×W×H) | 450×400×500 mm |
Net weight | 75 kg |
Power supply | AC220 V ± 10 % , 50 Hz |
The crush tester is used to test crush strength of paper & paperboard using different auxiliary appliances across paper & printing, packaging industry.
Available Range :
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustableRelated Models :
Model | Measurement range | Measuring scope | Folding angle | Tensile scope | Folding head suture size | Folding radius | Resolution | Accuracy | Variability | Speed | Vacuum system volume (ml) | Contact pressure | Vacuum scope | Air volume (50.66 kPa down to 48.00 kPa) | Maximum distance | Compression speed | Clamp pressure | Diameter of upper clamp | Diameter of lower clamp | Pneumatic pressure | Film resistance | Dimension (L×W×H) | Net weight | Power supply |
TP-A10 | - | - | - | - | - | - | - | Chromaticity co-ordinate 0.0001 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 23 kg | 220 V ± 10 %, 50 Hz |
TP-A11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 20 kg | 220 V ± 10 %, 50 Hz |
TP-B10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 15 kg | 220 V ± 10 %, 50 Hz |
TP-B11 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 kg | 220 V ± 10 %, 50 Hz |
TP-B12 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 40 kg | 220 V ± 10 %, 50 Hz |
TP-B20 | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 55 kg | 220 V ± 10 %, 50 Hz |
TP-C10 | 0 to 100° SR | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C20 | 0 to 200 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-D10 | 0.01 to 10 N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-E20 | - | - | - | - | - | - | - | 0.01 or 0.001 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E21 | - | - | - | - | - | - | - | 0.01 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-F10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-G10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-H10 | - | - | - | - | - | - | - | ± 1% | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 mm/ min | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 10 mm/ min | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J12 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J20 | - | - | - | - | - | - | 0.1 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J21 | - | - | - | - | - | - | 0.1 mN | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-K10 | 0 to 5600 kPa | - | - | - | - | - | - | ± 0.5 % F.S. | - | - | - | - | - | - | - | 170 ± 15 ml/min | ≥ 690 kPa | 31.5 ± 0.05 mm | 31.5 ± 0.05 mm | 0.45 to 0.6 MPa |
For bulge height = 10 mm, The pressure = 170 to 220 kPa For bulge height = 18 mm, The pressure = 250 to 350 kPa |
480×420×600 mm | 65 kg | AC220 V ± 10 % , 50 Hz |
TP-K11 | 50 to 1600 kPa-paper and 50 to 5600 kPa-paper | - | - | - | - | - | 0.01 kPa | ≤± 0.5 % | - | - | - | - | - | - | - | 95 ± 5 ml/min | 400 kPa to 1200 kPa(adjustable) | 30.5 ± 0.1 mm | 33.1 ± 0.1 mm | 0.3 to 0.5 MPa | (9±0.2)mm/(30±5)kPa | 428×318×412 mm | 50 kg | AC220 V ± 10 % , 50 Hz |
TP-L10 | 5 to 500 N, 50 to 3000 N | - | - | - | - | - | 1 N | ± 1 % | ≤ 1 % | 12.5 ± 2.5 mm/min | - | - | - | - | 78 mm | - | - | - | - | - | - | 450×400×500 mm | 75 kg | AC220 V ± 10 % , 50 Hz |
TP-L20 | - | ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s) | - | - | - | - | - | ±0.1 s within 300 s | - | - |
Bigger volume: 380 ± 1 Smaller volume: 38 ± 1 |
100 ± 2 kPa |
I) 50.66 to 48.00 II) 50.66 to 48.00 III) 50.66 to 29.33 Automatic: No limit |
Big vacuum volume: 10.00 ± 0.20 ml Small vacuum volume: 1.00 ± 0.05 ml |
- | - | - | - | - | - | - | 325×390×430 mm | 30 kg | AC220 V ± 10 % , 50 Hz |
TP-M10 | - | 0 to 99999 s | 135° ± 2° | 4.9 to 14.7 N | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm | 0.38 ± 0.02 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 320×320×450 mm | 35 kg | AC220 V ± 10 % , 50 Hz |
TP-E30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J11 | - | - | - | - | - | - | 0.001lbf/in² | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |