Automatic horizontal tensile tester TP-B12 is adopted with pneumatic clamps to minimize the error by proper holding of the sample. With the advanced ARM technology, it has strong data processing functions. The large LCD touch screen interface makes it easy to operate the tester. Tensile tester can test tensile strength, tensile force, tensile energy absorption, fracture length, tensile index, 180° peel strength of paper, paperboard, plastic film & other non-metal materials.
Request QuoteSample (size) length | 180 mm (180, 150, 100, 90, 50 mm adjustable) |
Sample width | 15 mm |
Measuring range | 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N |
Accuracy | ± 1 % |
Tensile strength velocity | 1 to 399 mm/min (adjustable) |
Tensile return velocity | 1 to 399 mm/min (adjustable) |
Sample loading | Semi-automatic , can clamp the sample using hands |
Dimension (L*W*H) | 800 × 270 × 200 mm |
Net weight | 40 kg |
Power supply | 220 V ± 10 %, 50 Hz |
Tensile horizontal tester is used in paper, paperboard, plastic film & other non-metal materials industry to test tensile strength, tensile force, tensile energy absorption, fracture & other parameters.
Available Range :
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm Sample (size) length : 38×70 mm Sample (size) length : 90 to 200 mm Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable) Sample (size) length : 0 to 200 mm adjustableRelated Models :
Model | Sample (size) length | Sample width | Measuring range | Measurement mode | Stability | Accuracy | Tensile strength velocity | Tensile return velocity | Sample loading | Clamp air pressure | Repeatability | System | Light source | Zero drift | Indication drift | Indication error | Test speed | Repeatability error | Mirror reflection error | Light measurement | Storage | Dimension (L*W*H) | Net weight | Power supply |
TP-A10 | Diameter ≥30 mm, Thickness ≤ 40 mm | - | - | Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b | ≤ 0.1 within 30 min | Chromaticity co-ordinate 0.0001 | - | - | - | - | Rx, Ry and Rz s ≤ 0.1 chromaticity co-ordinate s ≤ 0.0010, R457 s ≤ 0.10 | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150 mm, testing hole diameter 30 mm | - | - | - | - | - | - | - | CIE whiteness (Ganz whiteness W10, Color cast value TW10), WH hunter whiteness, YI Yellowness, ISO brightness R457 | 9 reference samples | 360 × 264 × 400 mm | 23 kg | 220 V ± 10 %, 50 Hz |
TP-A11 | Diameter ≥30 mm, Thickness ≤ 40 mm | - | - | - | - | - | - | - | - | - | - | D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm | D65 as illuminating source | ≤ 0.1 % | ≤ 0.1 % | ≤ 0.5 % | - | ≤ 0.1 % | ≤ 0.1 % | - | - | 360 × 264 × 400 mm | 20 kg | 220 V ± 10 %, 50 Hz |
TP-B10 | 38×70 mm | - | (1-500) mN.m (divided into 7 small ranges) | - | - | - | - | - | - | - | - | - | - | - | - | 0.02 | (200° ± 20°)/ min | - | - | - | - | 220 × 230 × 350 mm | 15 kg | 220 V ± 10 %, 50 Hz |
TP-B11 | 90 to 200 mm | 15 mm, 25 mm, 50mm | 0 to 30, 0 to 100 N,0 to 300 N | - | - | ± 1 % | 1 to 399 mm/min (adjustable) | 1 to 399 mm/min (adjustable) | Full automatic to clamp the sample | 0.4 to 0.6 MPa | - | - | - | - | - | - | - | - | - | - | - | 920 × 420 × 300 mm | 65 kg | 220 V ± 10 %, 50 Hz |
TP-B12 | 180 mm (180, 150, 100, 90, 50 mm adjustable) | 15 mm | 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | - | ± 1 % | 1 to 399 mm/min (adjustable) | 1 to 399 mm/min (adjustable) | Semi-automatic , can clamp the sample using hands | - | - | - | - | - | - | - | - | - | - | - | - | 800 × 270 × 200 mm | 40 kg | 220 V ± 10 %, 50 Hz |
TP-B20 | 0 to 200 mm adjustable | 15 mm | 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N | - | - | ± 1 % | 1 to 399 mm/min (adjustable) | 1 to 399 mm/min (adjustable) | - | - | - | - | - | - | - | - | - | - | - | - | - | 450 × 550 × 120 mm | 55 kg | 220 V ± 10 %, 50 Hz |
TP-C10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-C30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-D10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-E20 | - | - | 0 to 4 mm | - | - | 0.01 or 0.001 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-E21 | - | - | 0 to 20 mm | - | - | 0.01 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-F10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-G10 | - | 15 mm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-H10 | - | - | 10 to 1000 mN | - | - | ± 1% | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I10 | - | - | 0.1 to 10 kN | - | - | - | - | - | - | - | - | - | - | - | - | < ± 1% | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-I11 | - | - | 1 to 50 kN | - | - | - | - | - | - | - | - | - | - | - | - | < ± 1% | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J10 | - | - | 0 to 1000 ml/min | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-J12 | - | - |
A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 % |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | AC220 V ± 10 % , 50 Hz |
TP-J20 | - | - | 0 to 1000 mN | - | - | - | - | - | - | - | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - |
TP-J21 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
TP-K10 | - | - | - | - | - | ± 0.5 % F.S. | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 65 kg | AC220 V ± 10 % , 50 Hz |
TP-K11 | - | - | - | - | - | ≤± 0.5 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 50 kg | AC220 V ± 10 % , 50 Hz |
TP-L10 | - | - | - | - | - | ± 1 % | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 kg | AC220 V ± 10 % , 50 Hz |
TP-L20 | - | - | - | - | - | ±0.1 s within 300 s | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 30 kg | AC220 V ± 10 % , 50 Hz |
TP-M10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 35 kg | AC220 V ± 10 % , 50 Hz |
TP-E30 | - | - | 0 to 5 mm | - | - | - | - | - | - | - | - | - | - | - | - | ± 0.0025 mm or ± 0.5 % | - | - | - | - | - | - | - | - |
TP-J11 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |